Site icon BE Analytic Solutions LLP

Environmental and Reliability Testing

Environmental and Reliability Testing

Test Facilities

BE Analytic has established a world-class test facility for quality and reliability assurance of different Mechanical, Electronic and Electro-Mechanical Products. The infrastructure includes a climatic testing lab, dynamic testing lab, HALT and HASS. Environmental and Reliability testing labs are suitable for performing ESS, Vibration tests, Altitude tests, Thermal cycling tests, Thermal shock tests, Humidity tests, High-temperature tests, Low-temperature tests, Water Ingress protection tests, Solid Ingress protection tests, Mechanical shock and Bump tests, Salt spray test, Drop test and different kinds of environmental tests as per JSS 55555 & MIL-STD, IEC-60529, EN, DIN and IS0-20653, GS 95024-3-1, SAE J1455, ASTM C 150 specifications and determine whether the systems/subsystems perform consistently in the Service environment or not.

BE Analytic also helps develop Test plans for Reliability Growth Analysis, Reliability Demonstration, Burn-in, HALT and HASS screens. Apart from performing compliance related tests, we also do testing of equipment for Failure Mode Analysis and Reliability/MTBF estimation during prototype phases. This helps companies identify the failure modes and compare them with warranty goals set which will in turn reduce the cost and time of the product development.

For different standards, we perform various kinds of tests in our Environmental Testing Lab. The tests that we perform are mentioned below.

ALTITUDE (CATH) TEST

Altitude Testing (Cath Chamber) | Environmental Testing Lab in Bangalore | NABL & DGAQA Accredited Lab in Bangalore
Chamber Workspace800mm x 850mm x 900mm
Temperature Range -70⁰C to 180⁰C ±2⁰C
Rate of Change of Temp.5°C/min as per IEC 60068-3-5
Humidity Range15% TO 95% RH ±3%RH
in a Climatic Range of 10°C to 85°C
Altitude RangeAtmospheric to 10 mbar ±3mbar
Altitude RateAtmospheric to 100 mbar within 25-30 minutes
Atmospheric to 10 mbar within 40-45 minutes
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1
Altitude Test
MIL-STD 202G (conditions 105C, A/B/C/F)
2
Low Pressure (Altitude) test
MIL-STD 810G (condition 500.5)
3
High Altitude test, Low Altitude test, Decompression test
IEC 60068-2-39
4
Combined cold test
IEC 60068-2-40
5
Low Air Pressure test
JIS W 0812

Altitude Testing simulates the operation, performance and shipment of a product at different altitudes. These tests typically simulate the low air pressure when operating a product at a high altitude or shipping a product by air. In order to ensure the safety of the product altitude test is most important.
Altitude test is also called as Low Pressure test, Decompression test, High Altitude test, Low Altitude test, Combined cold test and Low Air Pressure test as per various test standards. BE Analytic will ensure that we conduct and perform altitude tests for your products efficiently to reach high-quality standards.

VIBRATION TEST

Vibration Testing lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab
Rated Force2500Kgf
Frequency Range 5 to 2500Hz
Maximum Acceleration100g
Maximum Velocity1800mm/s
Displacement51mm
Payload Capacity350Kg
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Sine on Random
Sine:
IS 9000(Part8)
IEC 60068-2-6
MIL-STD-810F
JSS 55555: 2012 Rev 1
JSS 50101
JIS D1601
Mixed Mode:
IEC 60062-2-80 (Part 2);80
MIL-STD-810G
Random:
IEC 60068-264
IEC 61373
2.
Sine
3.
Random
4.
Mixed
5.
Shock
6.
Bump

Vibration Testing is used to demonstrate a product’s ability to resist dynamic loads and fluctuation without losing critical functional or structural integrity under specified loads. It can be used to identify accumulated stress effects and the resulting mechanical weaknesses and performance flaws.
We conduct various kinds of vibration tests like Sine on Random vibration, Sine vibration, Random vibration test, Mixed mode vibration test, Mechanical shock testing and Bump test in our laboratory as per customer requirements.

SINE VIBRATION AND MECHANICAL SHOCK TEST

Rated Force4000 Kgf
Frequency Range 5 to 2000Hz
Maximum Acceleration160g
Maximum Velocity2000mm/s
Displacement70mm
Payload Capacity500Kg
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Sine on Random
Sine:
IS 9000(Part8)
IEC 60068-2-6
MIL-STD-810F
JSS 55555: 2012 Rev 1
JSS 50101
JIS D1601
Mixed Mode:
IEC 60062-2-80 (Part 2);80
MIL-STD-810G
Random:
IEC 60068-264
IEC 61373
2.
Sine
3.
Random
4.
Mixed
5.
Shock
6.
Bump
Vibration Testing Lab in Bangalore| Environmental Testing Lab | NABL & DGAQA Accredited Lab

The purpose of Vibration Tests is to evaluate the effect caused on parts by vibration in a specified frequency range. We conduct various kinds of vibration tests like Sine on Random vibration, Sine vibration, Random vibration test, Mixed mode vibration test, Mechanical shock testing and Bump test in our laboratory as per customer requirements.

TROPICAL EXPOSURE AND DEW TEST

Chamber Workspace1500mm x 1500mm x 1500mm
Temperature Range20⁰C to 180⁰C ±2⁰C
Humidity Range20% TO 98% RH ±3%RH
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1
Humidity Test
IEC 60068-2-78
2
Damp Heat
IEC 60068-2-30
3
Humidity test / Dew Test
MIL-STD-810F
4
Steady State Humidity test
ISO 16750-4
5
Tropical Exposure test
JSS 55555
6
Damp Heat (Cyclic), Damp Heat (Moisture Resistance)
JSS 50101
Humidity and Environmental Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab

Tropical Exposure test is a type of humidity test that helps in the determination of corrosion rates in materials. In this test, the material/product is exposed to various environmental factors (temperature and humidity) and corrosive products to study the impact of corrosion on certain industrial materials.
It is a vital part of quality control that is usually performed during product development in order to ensure the safety and quality of the products. 
BE Analytic offers a range of thermal cycling test services like Humidity Test, Damp Heat, Tropical Exposure test, Dew Test, Steady state humidity test and Moisture Resistance test as per various Industry standards.

THERMAL SHOCK TEST

Thermal Shock Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab
Basket Size450mm x 550mm x 600mm
Temperature Range-65⁰C to 180⁰C
Change Over Time12 Sec.
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1
Thermal Shock test
IEC 60068-2-14 (tests Na &Nb)
IEC 60068-2-30
2
Temperature Shock test
MIL-STD-810F
3
Rapid Temperature Cycling test (THERMAL SHOCK)
JSS 55555
4
Thermal Shock testing
IS 9000 (Part 15,Sec I & Sec II)

Thermal shock testing is conducted to determine if equipment can withstand sudden changes in the temperature of the surrounding atmosphere without experiencing physical damage or deterioration in performance. As a result of exposure to sudden temperature changes the operation of the temperature shock test items may be affected either temporarily or permanently. Thermal shock testing reduces the risk of product failure in the field by replicating a quick transition between two extreme temperatures. 
BE Analytic offers a range of thermal shock testing services like Thermal Shock, Temperature Shock, Rapid Temperature Cycling (THERMAL SHOCK) and Thermal Shock testing as per various Industry standards.

TEMPERATURE AND THERMAL SHOCK TESTING

Chamber Workspace420*420*615
Temperature Range -65⁰C to 180⁰C
Change over time12 Sec
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1
Thermal Shock test
IEC 60068-2-14 (tests Na &Nb)
IEC 60068-2-30
2
Temperature Shock test
MIL-STD-810F
3
Rapid Temperature Cycling test (THERMAL SHOCK)
JSS 55555
4
Thermal Shock testing
IS 9000 (Part 15,Sec I & Sec II)
Thermal Shock Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab

Thermal shock testing is conducted to determine if equipment can withstand sudden changes in the temperature of the surrounding atmosphere without experiencing physical damage or deterioration in performance. As a result of exposure to sudden temperature changes, the operation of the temperature shock test items may be affected either temporarily or permanently. Thermal shock testing reduces the risk of product failure in the field by replicating a quick transition between two extreme temperatures. 
BE Analytic offers a range of thermal shock testing services like Thermal Shock, Temperature Shock, Rapid Temperature Cycling (THERMAL SHOCK) and Thermal Shock testing as per various Industry standards.

HIGH TEMPERATURE TEST

High Temperature Testing lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab
Chamber Workspace 500mm x 500mm x 500mm
Temperature RangeAmbient to 180⁰C, ±2⁰C
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
High Temperature Test
IEC 60068-2-1
IEC 60068-2-14
IS 9000 (Part 3)
IS 9000 (Part 4)
MIL-STD-810F
JSS 55555
ISO 16750-4
JSS 50101
2.
High Temperature Storage
3.
High Temperature Storage Cum Operation
4.
High Temperature Operation
5.
Power on Burn-In Test

High-temperature testing reduces the risk of product failure in the field by simulating the temperature conditions that products are exposed to during their lifetime. The test specification defines the applied temperatures and test conditions, these may be to test the equipment’s operational limits or to test the equipment’s survivability at more extreme storage temperatures. 
BE Analytic offers a range of testing services like High-Temperature Tests, High-Temperature Storage Tests, High-Temperature Storage Cum Operation Tests, High-Temperature Operation Tests and Power on Burn-In Tests as per various Industry standards.

HIGH TEMPERATURE STORAGE TEST

Chamber Workspace 1000mm x 1000mm x 1000mm
Temperature RangeAmbient to 180⁰C, ±2⁰C
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
High Temperature Test
IEC 60068-2-1
IEC 60068-2-14
IS 9000 (Part 3)
IS 9000 (Part 4)
MIL-STD-810F
JSS 55555
ISO 16750-4
2.
High Temperature Storage
3.
High Temperature Storage Cum Operation
4.
High Temperature Operation
High Temperature Storage Testing Lab in Bangalore | Environmental Testing Lab in Bangalore | NABL & DGAQA Accredited Lab

High-temperature storage test reduces the risk of product failure in the field by simulating the temperature conditions that products are stored in high-temperature conditions for a long time during their lifetime. The test specification defines the applied temperatures and test conditions, these may be to test the equipment’s operational limits or to test the equipment’s survivability at more extreme storage temperatures. 
BE Analytic offers a range of testing services like High Temperature Tests, High Temperature Storage Tests, High Temperature Storage Cum Operation Tests, High Temperature Operation Tests and Power on Burn-In Tests as per various Industry standards.

BURN IN TEST

High Temperature Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab
Chamber Workspace 800mm x 800mm x 900mm
Temperature RangeAmbient to 200⁰C, ±2⁰C
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
High Temperature Test
IEC 60068-2-1
IEC 60068-2-14
IS 9000 (Part 3)
IS 9000 (Part 4)
MIL-STD-810F
JSS 55555
ISO 16750-4
JSS 50101
2.
High Temperature Storage
3.
High Temperature Storage Cum Operation
4.
High Temperature Operation
5.
Power on Burn-In Test

The Burn In Test is conducted to check product condition in the field by simulating the temperature conditions that products are stored in high temperatures in power conditions for a long time during their lifetime. The test specification defines the applied temperatures and test conditions, these may be to test the equipment’s operational limits or to test the equipment’s survivability at more extreme storage temperatures. 
BE Analytic offers a range of testing services like High-Temperature Tests, High-Temperature Storage Tests, High-Temperature Storage Cum Operation Tests, High-Temperature Operation Tests and Power on Burn-In Tests as per various Industry standards.

LOW TEMPERATURE TEST

Chamber Workspace800mm x 800mm x 900mm (W*D*H)
Humidity Range30% to 98% RH
Temperature Range-70⁰C to 200⁰C
Ramp Rate10⁰C/Min. Average
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Low Temperature Test
IEC 60068-2-14
IS 9000 (Part 2)
IS 9000 (Part 14)
MIL-STD-810F
JSS 55555
IEC 60068-2-1
2.
Low Temperature Storage
JSS 50101
IEC 60068-2-1
IEC 60068-2-14
3.
Low Temperature Storage Cum Operation
4.
Low Temperature Operation
5.
Thermal Cycling
IEC 60068-2-14 (tests Na &Nb)
IS 9000 (Part 15,Sec I & Sec II)
MIL-STD-810F
JSS 55555
Low Temperature Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab

Low-temperature test reduces the risk of product failure in the field by simulating the temperature conditions that products are stored in low-temperature conditions for a long time during their lifetime. The test specification defines the applied temperatures and test conditions, these may be to test the equipment’s operational limits or to test the equipment’s survivability at more extreme storage temperatures. 
BE Analytic offers a wide range of testing services like Low-Temperature Tests, Low-Temperature Storage Tests, Low-Temperature Storage Cum Operation Tests and Low-Temperature Operation Tests as per various Industry standards.

THERMAL CYCLING TEST

Thermal Cycling Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab
Number of Equipment2
Chamber Workspace1000mm x 1000mm x 1000mm
Temperature Range-65⁰C to 180⁰C
Ramp Rate10⁰C/Min. Average
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Low Temperature Test
IEC 60068-2-14
IS 9000 (Part 2)
IS 9000 (Part 14)
MIL-STD-810F
JSS 55555
IEC 60068-2-1
2.
Low Temperature Storage
IEC 60068-2-1
IEC 60068-2-14
JSS 50101
3.
Low Temperature Storage Cum Operation
4.
Low Temperature Operation
5.
Thermal Cycling
IEC 60068-2-14 (tests Na &Nb) IS 9000 (Part 15,Sec I & Sec II) MIL-STD-810F JSS 55555

Thermal Cycling or Temperature Cycle testing is performed on materials or products to determine the resistance of exposure to alternating extremes of high and low temperatures. Conducting thermal cycling tests during product development will assist in determining

  1. The existence of thermal coefficient mismatches.
  2. The sensitivity of these mismatches to repeated temperature excursions

BE Analytic offers a range of thermal cycling test services like, Thermal Cycling, Low Temperature Test, Low Temperature Storage, Low Temperature Storage Cum Operation, Low Temperature Operation to simulate different scenarios.

SALT SPRAY, SALT FOG AND CORROSION TESTING

Chamber Workspace300 litres
Temperature Range Ambient to 50°C
Ramp Rate2°C/min
Humidity Range95-100%RH
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Salt Spray Test
Salt corrosion test
Cyclic Salt Spray and Humidity Test
Salt spray humidity test
Salt Fog test
IEC 60068-2-11
IEC 60068-2-52
IS 9000 (Part 2)
ASTM B 117 Rev A
MIL-STD-810F
JSS 55555
JIS Z 2731
2.
Mixed Gas test
IEC 60068-2-60
Salt Spray and Corrosion Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab

Salt Spray Test and Salt Corrosion Testing reduce the risk of product failure in the field by simulating the equipment’s ability to withstand the effects of corrosion and giving a general indication of corrosion resistance. 
The Salt Spray test is a corrosion testing method that uses high-saline environments to measure the corrosion resistance of products, paints and coatings over extended periods. 
BE Analytic offers a wide range of testing services like Salt spray test, Cyclic salt spray and humidity test, Salt corrosion test and Salt fog test as per various Industry standards. 
BE Analytic also conducts a Mixed gas test is an accelerated environmental corrosion aging test that provides contact with harsh chemical pollutants commonly found in the atmosphere. The test specifically evaluates the corrosion of electrical components due to exposure to atmospheric gasses and contaminants. This test allows manufacturers to test for the build-up of corrosion that leads to the reduced performance of electrical components, providing an accelerated environment to determine a product’s life span as well as identify potential failure points. These results allow manufacturers to reduce premature wear and liability. 

DUST AND SAND TEST (Solid Ingression Protection Test)

Dust and Solid Ingress Protection Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab
Chamber Workspace1000*1000*1000 mm
Test TypeDust Ingress Protection
Air Flow RateUpto18m/s
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Dust Ingress Protection
IP5X- Limited Ingress
Protection
IP6X- Dust Tight Protection
IP5K- Dust Protected
IP6K- Dust Tight
IEC 60529
ISO 20653
2.
IP1X- Solid Foreign Object50mm Diameter Sphere
3.
IP2X- Solid Foreign Object12mm Diameter Test Finger
4.
IP3X- Solid Foreign Object2.5mm Steel Wire
5.
IP4X- Solid Foreign Object1mm Steel Wire

Dust and Sand tests are the types of Ingress protection (IP) testing that reduce the risk of product failure in the field by assessing the degree of protection provided against mechanical intrusion, dust, accidental contact and water into casings and enclosures. 
BE Analytic offers a wide range of solid IP testing services like IP1X, IP2X, IP3X, IP4X, IP5X, IP6X and IPX6K as per various Industry standards.

RAIN TEST (Water Ingression Protection Test)

Chamber Workspace 1000*1000*1000 mm
Test TypeWater Ingress Protection
SL.No. Specific Test Perform Water Flow Rate Pressure Rotating Speed of Table Test Duration
1.
IPX1- Dripping Water
1mm/min, ±0.5
NA
1 RPM
10 min
2.
IPX2- Dripping Water when tilted up to 15°
3mm/min, ±0.5
NA
1 RPM
2.5 min for each tilt position
3.
IPX3- Spraying Water up to 60° Angle
0.7 L/min, ±0.5% per hole
80 to 100kPa
1 RPM
5 min
4.
IPX4- Splashing Water in all direction
10 L/min, ±0.5% per hole
80 to 100kPa
1 RPM
5 min
5.
IPX5- Powerful Water Jet with Low Pressure
12.5 L/min
30kPa
1 RPM
3 min
6.
IPX6- Powerful Water Jet with High Pressure
100 L/min
1000kPa
1 RPM
3 min
7.
IPX6K- Powerful Water Jet with Extremely High Pressure
75L/min
1000kPa
1RPM
3 min
Water Ingress Protection Testing lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab

Rain and Water tests are the types of Ingress protection (IP) testing that reduce the risk of product failure in the field by assessing the degree of protection provided against mechanical intrusion, dust, accidental contact and water into casings and enclosures. 
BE Analytic offers a wide range of water IP testing services like IPX1, IPX2, IPX3, IPX4, IPX5, IPX6 and IPX6K as per various Industry standards.

IMMERSION TEST (IPX7 AND IPX8)

Water Immersion Testing (IPX7 & IPX8) | Environmental Testing Lab in Bangalore | NABL & DGAQA Accredited Lab
Chamber Workspace 1000*1000*1000 mm
Test TypeWater Ingress ProtectionImmersion Test
SL.No. Specific Test Perform Water Level Test Method Specification against which tests are performed Test Duration
1.
IPX7
Up to 1m
IEC 60529
ISO 20653
30 min
2.
IPX8
Deeper than 1m
As Per Customer Needs

Immersion tests are the types of Ingress protection (IP) testing that reduce the risk of product failure in the field by assessing the degree of protection provided against mechanical intrusion, dust, accidental contact and water into casings and enclosures. 
BE Analytic offers a wide range of water IP testing services like IPX7 and IPX8 as per various Industry standards.

HIGH PRESSURE JET AND WASH TEST (IPX9K)

Chamber Workspace 720*780*500 mm(L*B*H)
Test TypeWater Ingress Protection
SL.No. Specific Test Perform Water Flow Rate Water Temperature Pressure Rotating Speed of Table Test Duration Test Method Specification against which tests are performed
1.
IPX9KPowerful High Temperature Water Jets
14-16
80ºC ± 5°C Deviating temperatures may be agreed
80-100 bar
5 RPM
30 Sec/ Nozzle
IEC 60529
ISO 20653
High Pressure Water Ingress Protection Jet Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab

High-Pressure Wash or IPX9K test is one of the types of Ingress protection (IP) testing that reduces the risk of product failure in the field by assessing the degree of protection provided against mechanical intrusion, dust, accidental contact and water into casings and enclosures. In this test, the product is tested with hot water of higher temperature which is sprayed onto the product surface with extreme pressure conditions to check the capability of the product stability.
BE Analytic offers a wide range of water IP testing services like IPX9K, High-pressure jet stream test and High-pressure wash test as per various Industry

WATER SPRAY TEST (IPX4K)

SL.No. Specific Test Perform Water Flow Rate (LPM) Water Temperature Water Pressure at Rain or Spray Nozzle (Gauge Pressure) Number of Rain or Spray Nozzle Test Duration Test Method Specification against which tests are performed
1.
Spray Test – S1
24.5
Ordinary Temperature
0.10 Mpa
40
As Per Customer Need
JIS D 0203
2.
Spray TestS2
39.2
Ordinary Temperature
0.30MPa
40
As Per Customer Need
JIS D 0203

Water spray test or IPX4K test is one of the types of Ingress protection (IP) testing that reduces the risk of product failure in the field by assessing the degree of protection provided against mechanical intrusion, dust, accidental contact and water into casings and enclosures. In this test product is tested with water, through the holes of an oscillating tube which is sprayed onto the product surface to check the capability of the product stability.
BE Analytic offers a wide range of water IP testing services like IPX4K, Oscillating water test and JIS test as per various Industry

BUMP TEST

Bump Testing lab | Environmental Testing Lab in Bangalore| NABL & DGAQA Accredited Lab
Maximum Acceleration100g
Bump (Pulse) Duration3 to 18 milli second
Bump rate control1 to 3 Bump per second.
Payload Capacity100 Kg
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Bump Test
JSS 55555: 2012 Rev 1
JSS 50101
JIS D1601
MIL-STD-810G

The Bump test is a vibration analysis technique that allows us to identify resonances and propose modifications in machine structures and components to alter their natural frequencies or even design dynamic vibration absorbers to attenuate resonant energy.

DROP TEST AND BENCH HANDLING TEST

Testing Height (Drop Height)Minimum 380mm & Maximum 1800mm
Max. Dimension of Box to be tested500*500*500 mm (L*W*H)
Max. Weight of Box to be tested60 Kg
Base Dimension (Floor)1200 * 900 mm
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1
Drop Test, Transit drop test
MIL STD 810G
2
Toppling test
JSS 55555
3
Bench Handling test
MIL STD 810G
Drop and Bench Handling Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab

Drop test is used to evaluate how well the product design and materials will perform when it is exposed to an amount of external impact force. It is the best way to determine whether a product is suitable for use in environments where this kind of impact might happen
Drop testing our products gives us an opportunity to make alterations and modifications before our products go into the market. It means we can confidently say that this product will provide acceptable standards or protection if an accident were to happen.

COLD WATER SPRAY TEST

Cold Water Spray Testing Lab in Bangalore | BE Analytic Solutions LLP
Chamber Workspace1500mm x 1500mm x 1500mm
Chamber Temp Range20ºC to 180ºC
Water Temp Range0 to 4ºC
Humidity Range20% TO 98% RH ±3%RH

The Ice-water test or Cold-water splash test is used to check the product performance testing in the splashed areas on vehicles such as automotive exterior instruments and parts. In the process of driving, especially when driving on wet roads in winter, the impact of frozen mud water will occur. The Cold water thermal shock test is to simulate the splash of cold water on hot systems/components through equipment.

HUMIDITY AND DAMP HEAT TEST

Humidity and Environmental Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab
Chamber Workspace750mm x 800mm x 800mm
Temperature Range20⁰C to 125⁰C ±2⁰C
Humidity Range30% TO 95% RH ±3%RH
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1
Humidity Test
IEC 60068-2-78
2
Damp Heat
IEC 60068-2-30
3
Humidity test / Dew Test
MIL-STD-810F
4
Steady State Humidity test
ISO 16750-4
5
Tropical Exposure test
JSS 55555
6
Damp Heat (Cyclic), Damp Heat (Moisture Resistance)
JSS 50101

Humidity test is a type of corrosion analysis technique that helps in the determination of corrosion rates in materials. In this test, the material/product is exposed to various environmental factors (temperature and humidity) and corrosive products to study the impact of corrosion on certain industrial materials.
It is a vital part of quality control that is usually performed during product development in order to ensure the safety and quality of the products. 
BE Analytic offers a range of thermal cycling test services like Humidity Test, Damp Heat, Tropical Exposure test, Dew Test, Steady state humidity test and Moisture Resistance test as per various Industry standards.

OZONE TEST

Chamber Workspace600mm X 600mm X 600mm
Temperature Range15⁰C to 45⁰C ±5⁰C
Humidity Range25% TO 65% RH
±5%RH
Ozone Concentration Level0.1 PPM to 9 PPM
±5%RH
Sensor Type Electro-Chemical type
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Ozone Test
ASTM D 518 IS-3400 (Part-20)
ASTM D 1149 ISO 1431-1 : 1989
ASTM D 1171
ASTM D 3395
ASTM D 4575
BIS, ISO, DIN, MIL
Ozone Testing Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab

Ozone testing is a method used to determine a rubber or elastomer’s resistance to ozone degradation. The elastomer samples are placed in a special chamber that exposes them to ozone at a concentration and duration specified by a testing specification or standard.

FUNGUS TEST AND MOLD GROWTH TESTING

Fungus and Mold Growth Testing Lab in Bangalore | Environmental Testing Lab | NABL & DGAQA Accredited Lab
Testing Height (Drop Height)Minimum 380mm & Maximum 1800mm
Max. Dimension of Box to be tested500*500*500 mm (L*W*H)
Max. Weight of Box to be tested60 Kg
Base Dimension (Floor)1200 * 900 mm
SL.No. Specific Test Perform Test Method Specification against which tests are performed
1.
Mould Growth Test, Fungus Test
JSS 55555: 2012, MIL-STD-810G DO 160

Fungus test or Mold Growth test is used to assess the products’ ability to resist Fungus (mold) growth in elevated moisture conditions. Manufacturers can use fungus resistance testing results to guide them toward developing products that resist mold growth.

Exit mobile version